Permit Number - T15CM06053

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
08/31/2016 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
08/16/2016 REINFORCED MASONRY PRE-GROUT Partial Approval TOP OUT GARAGE GATE WALL SOUTH
TOP OUT SOUTH SIDE OF GARAGE WEST ENTRY WALLS ONLY
08/11/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/08/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/08/2016 REINFORCED MASONRY PRE-GROUT Partial Approval MISSING VERTS OPEN AREA 2ND FLOOR INSTALED ON SITE
07/07/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/07/2016 REINFORCED MASONRY PRE-GROUT Partial Approval top out at crash wall ok
07/06/2016 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
06/30/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/30/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 1st lift at crash wall ok, 2nd lift at west exterior to south ok1st floor
06/29/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/29/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 1- elevator and stairwell 2 topout ok
06/24/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/24/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 1-2nd lift at elevator on roof ok
2- stairwell #2 top out ok
06/22/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/22/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 1- 6th floorok to rock corridor lids only
06/09/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/09/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 1- units 305,307,310,312 ok to first layer lids.
2-1st and 2nd levels, ok 2nd lift approx 12' south of west wall at end of poured parking structure
06/08/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/08/2016 REINFORCED MASONRY PRE-GROUT Partial Approval top out at stairwell #1 ok
06/07/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/07/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 6th floor 4th lift stair 1 ok to grout
06/02/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/27/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/25/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/19/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/18/2016 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
05/17/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/16/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/12/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/11/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/05/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/03/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/02/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 3rd lift on 4th floor elevator.
04/28/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/26/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/25/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/22/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/20/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/15/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/14/2016 REINFORCED MASONRY PRE-GROUT Partial Approval stairwell #2 12ft, 2nd lift on electric room, 4ft on trash room, 12ft on west wall GL 4.5-2.3/A
04/13/2016 REINFORCED MASONRY PRE-GROUT Not ready for Inspection incomplete
04/11/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 1st lift at GL4.2-4.5/f.6-g, 4.4/f.6-e.2, e/3.5-4.4, 3.5/f-f.4.
04/07/2016 REINFORCED MASONRY PRE-GROUT Not ready for Inspection Not ready corrections not made.
04/06/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 3rd lift on stair #2 elevator from 3rd floor.
04/05/2016 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
04/04/2016 REINFORCED MASONRY PRE-GROUT Partial Approval GL a/1-5 1st lift
03/31/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 2nd lift from 3rd floor
02/29/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/16/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/11/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/09/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/02/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/01/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* 2nd LFT on elevator
01/20/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 5TH FLOOR 4' LIFT.