Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T15CM05141

Parcel: 128020830


Addresses:

6241 E 15TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
10/05/2015 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
08/12/2015 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/12/2015 MECHANICAL - INTERMEDIATE Denied PROVIDE A PERMIT FOR NEW WATER HEATER. FURNACE CANNOT BLOCK REMOVEAL OF WATER HEATER. CAP-OFF VENT IN CONDENSATE DRAIN. PVC MUST BE MIN 6" FROM SINGLE WALL VENT. T & P ON WATER HEATER CANNOT RUN UP HILL. PROVIDE A PAN UNDER WATER HEATER AND TERMINATE T & P INTO DRAIN PAN