Inspection History Details
Inspection Status: Approved
Inspection History: FIRE - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2015 | FIRE - FINAL | Approved | ||
| 10/27/2015 | FIRE - FINAL | Denied | Numbers 1,2,3,5,5,6, are corrected from last inspection Need to fire rate corridor to 1 hour walls, ceiling and 20 minute fire doors that self-close and latch shut, all hardware on doors are required to be fire rated i.e door hinges, door closer and door knob. Also need to show this work on approved plans. Need approved plans to show occupant load for the building, i.e. dining room, kitchen, bathrooms, break room ect. |
|
| 10/16/2015 | FIRE - FINAL | Denied | 1. Need seperate permit for hood supression system - new equipment need plans submitted for approval. 2. Exit sign for restroom hallway and emrgency lights 3. sign over front door needs to read " this door to remain unlocked while the building is occupied. 4. Need to see seating in place ( tables and chairs) 5. Need to test emergency lights and exit signs 5. Remove second door from the kitchen exit ( security door) 6. Remove holders for drop bar on inside of kitchen exit door. |