Permit: T15CM04614

Parcel: 119222580


Addresses:

1899 W MERLIN RD

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/23/2015 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
12/22/2015 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :23No Description.| 99946
1 REPLACE UNION TO BE BURIED UNDERGROUND
2. DRIP LEG APPLIANCE
3. PRIMER AND TAPE ALL JOINTS
07/09/2015 PLUMBING - GAS PRESSURE TEST Denied GAS LINE NOT HOLDING PRESSURE. TEST ALL GAS PIPING.WTR HTR VENT CONNECTOR NOT CONNECTED INTO DOUBLE WALL PROPERLY. USE A 15 LB GAUGE IN 1/10TH LB INCREMENTS TAPE WRAP GAS LINE TO 6" ABOVE GRADE AND USE TAPE PRIMER PRIOR TO TAPE