Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T15CM04265
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/31/2015 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
08/31/2015 | EXT METAL CLIPS/EXT SHEATHING | Approved | CHECKED TRUSS CALCS. CORRECTIONS HAVE BEEN MADE | |
08/28/2015 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1. NAIL OFF INTERIOR AND EXTERIOR SHEARWALLS- ALL STUDS. 2. NAIL H. D. STUDS ALL THE WAY UP. 3. RSP4 MISSING AT EAST TRIPLE STUD. 4 PROVIDE LADDER. |