Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T15CM03672

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
09/15/2015 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
06/10/2015 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/10/2015 PLUMBING - GAS PRESSURE TEST Denied BUILDING ADDRESSED AS 2737, CORRECT ADDRESSING. FACTORY COATED PIPING REQUIRED BELOW GRADE, EXPOSE FOR INSPECTION. 12" COVER REQUIRED. SEDIMENT TRAP REQUIRED AT WATER HEATER. TYPE B-VENT REQUIRED FOR WATER HEATER. ALIGN DRAFT DIVERTER OVER VENT OPENING. INSTALL NEW GAS FLEX AT WATER HEATER. ALSO, CO2 DETECTOR REQUIRED. 18' OF METALLIC WATER TUBING REQUIRED AT WATER HEATER. ALSO, SUPPORT TUBING. SUPPORT GAS PIPING DROP AT WATER HEATER.