Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2015 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/18/2015 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 11/10/2015 | PLUMBING - INTERMEDIATE | Not ready for Inspection | not ready, put ABS under test, put PEX under test. Incomplete Inspection. |
|
| 11/09/2015 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 11/06/2015 | PLUMBING - INTERMEDIATE | Denied | REVERSE GRADE IN LAVATORY DRAIN. SANITARY TEES USED IN VENTING MUST SWEEP UPWARD. 101 WATER TEST IS REQUIRED ON DWV SYSTEM. |
|
| 11/03/2015 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |