Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T15CM03161

Parcel: 11015122C


Addresses:

5523 E GRANT RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T15CM03161

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
08/13/2015 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
08/07/2015 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
08/07/2015 PLUMBING - ROUGH, SOIL Partial Approval ALL AREAS EXCEPT MECHANICAL ROOM OK TO COVER. COMPLETE PREVIOUSLY NOTED CORRECTIONS
08/05/2015 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/05/2015 PLUMBING - ROUGH, SOIL Denied PROPER USE OF DRAINAGE FITTINGS (SWEEPS) DRY VENT SHALL RISE VERTICAL TO 6" ABOVE FLOOD LEVEL. FULL SIZED CLEANOUTS SHOWN. NO PLASTIC MAY BE EMBEDDED IN CONCRETE. TEST VAC LINE. SUPPORT PIPING
08/04/2015 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
08/04/2015 PLUMBING - ROUGH, SOIL Not ready for Inspection PROVIDE A TEST ON UNDERGROUND PLUMBING. PROVIDE DETAILS FOR NEW DOOR HEADERS