Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T15CM02864

Parcel: 121063160

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T15CM02864

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/20/2015 PLUMBING - FINAL Approved IVRS - Inspection :*
05/12/2015 PLUMBING - FINAL Not ready for Inspection NO ONE AT HOME. 2:40 PM.
05/08/2015 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/08/2015 PLUMBING - FINAL Denied SEAL FLASHINGS. PROVIDE ROOF ACCESS. CORRECT VENT COMMON TEE AND CONNECTIONS. LARGER APPLIANCE CONNECTS TO BOTTOM OF TEE, SMALLER APPLIANCE CONNECTS TO SIDE. SECURE ALL VENTS W/ SCREWS. INSTALL CO DETECTOR. CHECK T & P RELIEF VALVE
05/04/2015 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
05/04/2015 PLUMBING - FINAL Not ready for Inspection PROVIDE ACCESS. PROVIDE CO DETECTOR. TYPE B-VENT IS REQUIRED TO POINT OF TERMINATION