Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/15/2015 |
PLUMBING - FINAL |
|
Approved |
|
| 04/23/2015 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection :* |
| 04/23/2015 |
PLUMBING - FINAL |
|
Partial Approval |
PROVIDE A DOUBLE WALL VENT FROM FURNACE CLOSET THROUGH ROOF WITH AN APPROVED CAP. FURNACE VENT SHOULD BE TIED INTO BOTTOM OF TEE AND WATER HEATER INTO SIDE OF TEE. ALL CRIMPED ENDS TO GO SAME DIRECTION AS AIR FLOW. PROVIDE THREE SCREWS IN ALL JOINTS OF VENT CONNECTOR. DO NOT USE TAPE. 11 PSI TEST IS OK. OK TO CLEAR RESIDENTIAL GAS |