Permit: T15CM02664

Parcel: 125112590


Addresses:

3667 E BAKER PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/15/2015 PLUMBING - FINAL Approved
04/23/2015 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
04/23/2015 PLUMBING - FINAL Partial Approval PROVIDE A DOUBLE WALL VENT FROM FURNACE CLOSET THROUGH ROOF WITH AN APPROVED CAP. FURNACE VENT SHOULD BE TIED INTO BOTTOM OF TEE AND WATER HEATER INTO SIDE OF TEE. ALL CRIMPED ENDS TO GO SAME DIRECTION AS AIR FLOW. PROVIDE THREE SCREWS IN ALL JOINTS OF VENT CONNECTOR. DO NOT USE TAPE. 11 PSI TEST IS OK. OK TO CLEAR RESIDENTIAL GAS