Permit: T15CM02596

Parcel: 112031870


Addresses:

3302 N CHRISTMAS AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/02/2016 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/28/2016 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE A VENT FOR THE MASTER BATH LAVATORY DRAIN THAT RISES VERTICAL TO 42 INCHES AFF AND REVENT INTO THE 2 INCH VTR.
2- RETEST SANITARY SYSTEM.


*
07/26/2016 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE A VENT FOR THE LAVATORY DRAIN IN MASTER BATH.
2- SHALL PROVIDE THE REQUIRED SAFTEY PLATES THAT EXTEND 2 INCHES ABOVE SOLE PLATES AND BELOW THE TOP PLATES. REFERENCE SECTION 305.6 2012 IPC.
3- SHALL USE A SAN TEE FOR THE TRAP ARM AT A.W. BOX. 902.2 IPC.
4- NOTE. SHALL PROVIDE HAMMER ARRESTORS FOR A.W. BOX. THEY MAT BE LOCATED IN THE WASHER BOX OR PROVIDE THE ADD ON EXTERIORS ARRESTORS AT TIME OF FINAL INSPECTION.
5- RE TEST THE DWV SYSTEM.


*