Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/10/2015 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 04/09/2015 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 04/02/2015 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/02/2015 | PLUMBING - FINAL | Denied | ?? TEE IS DAMAGED, TAPE IS NOT A FIX. WH CONNECTOR SHALL SLOPE UPWARDS AT A MIN 1/4" PER FOOT. FURNACE REQUIRES AN INCREASER CLOSE TO UNIT CONNECTION. TPR DRIPPING | |
| 03/27/2015 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/27/2015 | PLUMBING - FINAL | Denied | CORRECT VENT CONNECTORS. REPLACE DAMAGED CONNECTION TEE. PROVIDE SLOPE, INCREASE AT FURNACE | |
| 03/25/2015 | PLUMBING - FINAL | Partial Approval | PROVIDE GALV VENT CONNECTORS @ WH SECURE WITH SCREWS ELECTRICAL BONDING EXTEND B VENT TERMINATION ABV COOLER |