Permit: T15CM01840

Parcel: 116150790

Inspection Status: Continued

Inspection History: ENGINEERING - FINAL

Date Description Inspector Results Comments
05/12/2015 ENGINEERING - FINAL Continued 1) COMPLETE SITE WORK PER APPROVED PLANS
2) REMOVE OR SEPARATE CONSTRUCTION DEBRIS AND MATERIALS FROM PUBLIC ACCESS, CALL FOR RE-INSPECTION
05/12/2015 ENGINEERING - FINAL Approved
05/05/2015 ENGINEERING - FINAL Not ready for Inspection THE SITE IS NOT AS SHOWN ON THE APPROVED PLANS, SEE THE COMMENTS NOTED ON THE INSPECTION SHEETS FOR THE OUTSTANDING ITEMS.
1) H.C PAVEMENT MARKINGS AND SIGN HAS NOT BEEN PLACED ACCORDINGLY. PAINT THE PAVEMENT MARKER AND INSTALL THE SIGN AT 7 FEET ABOVE THE PAVEMENT PRIOR TO RECALLING IN THIS INSPECTION.
2) THE EAST PARKING AREA IS PER THE APPROVED PLANS, THREE LEGAL SPACES ARE SHOWN ON THE APPROVED PLANS, ONLY TWO HAVE BEEN PROVIDED AT THIS TIME.
3) ALL PARKING LOCATIONS REQUIRE CONCRETE PARKING BLOCKS FOR, NONE HAVE BEEN INSTALLED.
4) THE HANDICAP ACCESS ISLE PER THE PLANS IS TO BE 6 FEET AND SHOULD HAVE AN ACCESS RAMP THAT IS ATLEAST 4 FEET WIDE. THE CURRENT ISLE IS ONLY 5 FEET WITH A 3 FOOT ACCESS RAMP.
5) THE EXISTING FRONT PORCH HAS BEEN DAMAGED IN THE AREAS WHERE THE CANOPY SUPPORT POST ARE LOCATED, MAKE THE NECESSARY REPAIRS PRIOR TO CALLING IN FOR THE FINAL INSPECTION.