Permit: T15CM01675

Parcel: 123141200


Addresses:

744 E LINDEN ST

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
07/28/2015 MECHANICAL - INTERMEDIATE Approved
06/12/2015 MECHANICAL - INTERMEDIATE Denied 1. REPLACE DRYER VENT.
2. OK TO INSULATE ALL EXCEPT HOME RUN WALL
06/11/2015 MECHANICAL - INTERMEDIATE Denied 1. DRYER VENT HAS MANY THINGS WRONG WITH IT. RECOMMEND A 2X6 WALL AND A MECHANICAL CONTRACTOR.
2. FIRE CAULK OR FOAM ALL OPENINGS IN NEW FIREBLOCKS.
3. BLOCK ALL DUCT BOOTS ON 3 SIDES.
06/08/2015 MECHANICAL - INTERMEDIATE Not ready for Inspection 1. NEED ELEC BANG PLATES. SECURE LIGHT AND FAN WIRES
2. R-6 DUCTS ONLY IF INSULATED ABOVE THEM - OR MUST BE R-8
3. BANG PLATE PEX - NE CORNER OF NW BEDROOM
4. NEED DRYER DUCT IN PLACE
5. NEED FIRE BLOCKING AT DROP CEILING - SW BEDROOM