Permit: T15CM01538

Parcel: 13336790A


Addresses:

410 N SCHRADER LN


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T15CM01538

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/17/2015 BUILDING - FINAL Approved IVRS - Inspection :*
06/30/2015 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
06/23/2015 BUILDING - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
NO ACCESS OR PHONE NUMBER
04/24/2015 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
04/24/2015 BUILDING - FINAL Denied CONDENSATE CANNOT TERMINATE ONTO THE PATIO. PROVIDE CABLE CONNECTORS AT DISCONNECT AND FAN COIL. CAP OFF VENT UPSTREAM OF TRAP. MARK UNIT DATA PLATE. PROVIDE A FILTER DOOR THAT COVERS THE ENTIRE OPENING. EXPOSE ELEC CONDUIT AT SPA. INSPECTION STOPPED. ITEMS WERE NOT CORRECTED
03/25/2015 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/25/2015 BUILDING - FINAL Denied TIGHTEN ALL FITTINGS ON ELEC CONDUIT TO SPA. PROVIDE APPROVED SUPPORTS FOR ELEC CONDUIT. PROVIDE APPROVED SUPPORT AT CONDENSOR ON ROOF. PROVIDE A DISCONNECT AT CONDENSOR. PROVIDE THE REQUIRED GFI RECEPTACLE ON ROOF. PLASTIC HOSE FROM PUMP NOT ALLOWED OUTDOORS. PROPERLY SECURE LINESET INSULATION TO LINESET AND PROVIDE A PROTECTIVE COATING. PROVIDE APPROVED ELEC CONDUIT ON ROOF TO A/C UNIT. TERMINATE CONDENSATE TO THE GROUND. EXPOSE CONDUIT UNDERGROUND TO SPA. PROVIDE A TRAP IN CONDENSATE DRAIN. PROVIDE A HOSE CLAMP ON CONDENSATE PUMP. PROVIDE A CABLE CONNECTOR AT FAN COIL AND DISCONNECT. PROVIDE THE FILTER COVER. MARK UNIT DATA PLATE WITH PROPER HEAT STRIP AND FUSE ACCORDINGLY.
03/17/2015 BUILDING - FINAL Partial Approval OK TO POUR FOOTINGS. PROVIDE A TRAP IN CONDENSATE DRAIN. PROVIDE AN OVERFLOW SENSOR. CONNECT OVERFLOW SENSOR ON PUMP. PROVIDE A COVER PLATE AT RECEPTACLE. WIRE SPLICES MUST BE IN A J BOX
PROVIDE A FILTER ACCESS DOOR
PROVIDE A DATA PLATE FOR FAN COIL
PROVIDE ACCESS TO ROOF
03/11/2015 BUILDING - FINAL Partial Approval IVRS - Inspection :*
03/11/2015 BUILDING - FINAL Partial Approval POSTS ARE NOT CENTERED ON FOOTINGS. PLEASE ADD MORE REBAR & CONCRETE IN FRONT OF EACH FOOTING & ALONG THE SIDE OF 1 OF THE FOOTINGS. PROVIDE A PERMIT FOR ALL NEW WORK INCLUDING NEW A/C EQUIPMENT & NEW ELECTRIC CIRCUIT TO A SPA
03/10/2015 BUILDING - FINAL Partial Approval IVRS - Inspection :*
03/10/2015 BUILDING - FINAL Partial Approval EXPOSE FOOTINGS AT EACH POST