Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T15CM01494
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/06/2015 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
04/02/2015 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
04/02/2015 | PLUMBING - INTERMEDIATE | Denied | LB 2552 - DWV PIPES OPEN (SAFETY HAZARD) PEX NOT SECURED IN WALLS. PEX NOT ISOLATED FROM METAL (GANG NAILERS, SAFETY PLATES). MISSING SAFETY PLATES AT MAIN SERVICE (1 1/4 FROM STUD FACE REQ PLATE) | |
03/25/2015 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
03/25/2015 | PLUMBING - INTERMEDIATE | Denied | CAP OPEN DWV DURING CONSTRUCTION FOR SAFETY. SECURE PEX, ISOLATE FROM METAL. PROVIDE LADDER ACCESS TO ATTIC SPACE. SUPPORT & SECURE ALL TUBING AS REQUIRED IN MANUFACTURERS INSTALLATION STANDARDS. SWIVEL CONNECTORS AT WASHER BOX MAY NOT BE CONCEALED. HAMMER ARRESTORS REQUIRED. ORIGINAL PIPING WAS 1", BRING 1" TO FIRST BATHROOM GROUP OR PROVIDE A PLAN. MIN AIR GAP REQUIRED AT TUB SPOUT. TEST ALL JOINTS, INCLUDING SHOWER & TUB CONENCTIONS TO DIVERTOR. |