Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 11/19/2015 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* |
| 06/16/2015 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
Changed from AP to PA to allow for reinspection. |
| 06/05/2015 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* |
| 06/05/2015 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
DWV IN WALLS W/ TEST THROUGH ROOF OK. WATER PIPE SIZING NOT PER PLAN. RECIRC (?) LOOP REQ 1" INSULATION. SECURE TUBING THROUGH WALLS. POINT OF VENT MAY NOT BE BELOW TRAP. DRY VENT SHALL RISE VERTICALLY TO 6" ABOVE FLOOD LEVEL OF FIXTURE |