Permit: T15CM00517

Parcel: 126172160


Addresses:

4017 E MONTECITO ST

Inspection Status: Approved

Inspection History: ELECTRIC - UNDERGROUND

Date Description Inspector Results Comments
08/05/2015 ELECTRIC - UNDERGROUND Approved SECTION R3802.5 INDICATES THAT BENDS IN CONDUIT MUST BE MADE SO AS NOT TO DAMAGE WIRING. ALTHOUGH THERE ARE MORE BENDS THAN THE NEC ALLOWS, THIS PROJECT IS REGULATED UNDER THE IRC AND THE WIRING HAS BEEN DETERMINED TO BE UNDAMAGED IN THE CONDUIT.
08/04/2015 ELECTRIC - UNDERGROUND Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/04/2015 ELECTRIC - UNDERGROUND Denied 7-90' FROM SERVICE TO SUBPANEL AT BUILDING - WIRE OK