Permit: T15CM00386

Parcel: 126061300


Addresses:

909 N MONTEZUMA AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
07/20/2015 BUILDING - FINAL Approved IVRS - Inspection :*
07/15/2015 BUILDING - FINAL Denied THE GARBAGE DISPOSAL DRAIN HAS BACK PITCH. STRAP THE DISHWASHER HOSE TO UNDERSIDE OF COUNTER TOP.
PROVIDE A 90 DEGREE ELBOW AT CONDENSATE TERMINATION. PROVIDE A TRAP IN CONDENSATE DRAIN. PROVIDE AN OVERFLOW SENSOR IN SECONDARY OUTDOORS ON LINE SET. USE A PRETECTIVE COATING EXCEED 3' LENGTH. PROVIDE SCREENS IN CONBUSTION AIR LOUVERS.
INSTALL WASHER AND DRYER MIN 18' ABOVE GARAGE FLOOR.
PROVIDE A CO2 SENSOR.
RELOCATE A/C DISCONNECT FROM BEHIND CONDENSING UNITS.
PROVIDE A PANEL SCHEUDLE. ALL BRANCH CIRCUITS TO HAVE ARE FAULT BREAKERS PER 2012 IRC.
OUTDOOR LIGHTS MUST BE SHIELDED.
07/13/2015 BUILDING - FINAL Not ready for Inspection NO ONE PRESENT AT 12:45.