Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2016 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/29/2016 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection :23No Description.| 99946 * |
|
| 02/25/2016 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 01/28/2016 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection :23No Description.| 99946 * |
|
| 07/23/2015 | PLUMBING - INTERMEDIATE | Denied | piping thru concrete shall be sleeved | |
| 06/01/2015 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 05/07/2015 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 05/07/2015 | PLUMBING - INTERMEDIATE | Partial Approval | RE-CALL INTERMEDIATE INSPECTION FOR SHOWER PAN LINER AND CLOSET FLANGE WHEN READY. CORRECT GAS PLANS AS NOTED | |
| 05/06/2015 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 05/01/2015 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/01/2015 | PLUMBING - INTERMEDIATE | Denied | COMPLY W/ ALL WORK SHOWN ON NEW PLAN. COMPLY W/ PREVIOUSLY NOTED CORRECTIONS. EXPOSE PIPING FOR INSPECTION. PEX REQUIRES SUPPORTS NOT EXCEEDING 32". CORRECT GAS PLAN. TDL IS 200 FEET. SUPPORT CLOSET FLANGE | |
| 03/20/2015 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/20/2015 | PLUMBING - INTERMEDIATE | Denied | YARD WATER W/ TEST OK. GAS PIPING AND MECH UNIT NOT SHOWN ON PLANS. I NEED PLANS TO CHECK SIZING OF PIPING & DUCT WORK. REV REQ FOR ALL CHANGES. SLEEVE GAS PIPING THROUGH MASONRY. ISOLATE PEX FROM GANG NAILERS. SECURE TUBING IN WALLS. SECURE CLOSET FLANGE. MISSING NAIL PLATES. ALSO, NAIL PLATES AT TOP & BOTTOM PLATES ARE REQ TO EXTEND 2" PAST. SUPPORT HORIZ ABS. KEEP OPEN PIPES CAPPED. | |
| 03/11/2015 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 03/11/2015 | PLUMBING - INTERMEDIATE | Partial Approval | DWV TEST THROUGH ROOF OK. ADD SUPPORTS OVERHEAD. SECURE CLOSET FLANGES TO F.F. |