Permit: T15CM00197

Parcel: 133090440


Addresses:

7851 E BELLEVUE ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
12/09/2016 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
03/29/2016 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :23No Description.| 99946
*
02/25/2016 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/28/2016 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :23No Description.| 99946
*
07/23/2015 PLUMBING - INTERMEDIATE Denied piping thru concrete shall be sleeved
06/01/2015 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
05/07/2015 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
05/07/2015 PLUMBING - INTERMEDIATE Partial Approval RE-CALL INTERMEDIATE INSPECTION FOR SHOWER PAN LINER AND CLOSET FLANGE WHEN READY. CORRECT GAS PLANS AS NOTED
05/06/2015 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
05/01/2015 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/01/2015 PLUMBING - INTERMEDIATE Denied COMPLY W/ ALL WORK SHOWN ON NEW PLAN. COMPLY W/ PREVIOUSLY NOTED CORRECTIONS. EXPOSE PIPING FOR INSPECTION. PEX REQUIRES SUPPORTS NOT EXCEEDING 32". CORRECT GAS PLAN. TDL IS 200 FEET. SUPPORT CLOSET FLANGE
03/20/2015 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/20/2015 PLUMBING - INTERMEDIATE Denied YARD WATER W/ TEST OK. GAS PIPING AND MECH UNIT NOT SHOWN ON PLANS. I NEED PLANS TO CHECK SIZING OF PIPING & DUCT WORK. REV REQ FOR ALL CHANGES. SLEEVE GAS PIPING THROUGH MASONRY. ISOLATE PEX FROM GANG NAILERS. SECURE TUBING IN WALLS. SECURE CLOSET FLANGE. MISSING NAIL PLATES. ALSO, NAIL PLATES AT TOP & BOTTOM PLATES ARE REQ TO EXTEND 2" PAST. SUPPORT HORIZ ABS. KEEP OPEN PIPES CAPPED.
03/11/2015 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
03/11/2015 PLUMBING - INTERMEDIATE Partial Approval DWV TEST THROUGH ROOF OK. ADD SUPPORTS OVERHEAD. SECURE CLOSET FLANGES TO F.F.