Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/28/2015 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 01/14/2015 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/14/2015 | ELECTRIC - FINAL | Denied | UNIT LOCKED SERV UPGRADE ADDED TO PERMIT WORK NOT COMPLETE 2 GROUND RODS6' MIN APART BOND GAS/WATER PIPING NEUTRAL CONDUCTOR (RISER) TO SMALL SHOULD BE #2 COPPER WHITE TAPE GROUNDED RECEPTS ON UNDERGROUND SYSTEM #4 SOLID TO GROUND RODS RISER CONDUIT NOT SUPPORTED USE QUALIFIED ELECTRICIAN TO DO WK |
|
| 01/07/2015 | ELECTRIC - FINAL | Denied | SERVICE ELEC IN NEED OF UPGRADE. EXISTING SYSTEM IS OUTDATED AND HAS BEEN ALTERED W/OUT PERMIT OR INSPECTION. TEP HAS DISCONNECTED THE RISER CONDUCTORS DUE TO HAZARDOUS WIRING. OBTAIN PERMIT FOR WK. ALSO OPEN G BX, WIRING UNSUPPORTED CONDUITS THRU OUT EXT OF HOME WTR HTR STORAGE ROOM IN BACK EXPOSE ROMEX IN BEDROOMS CEILINGS USE LICENSED QUALIFIED ELECTRICIAN |