Permit: T14OT01399

Parcel: 11105026F

Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Date Description Inspector Results Comments
12/15/2014 SIGN SITE REVIEW Approved REVISIONS APPROVED
12/01/2014 SIGN SITE REVIEW Correction Required Please make the following corrections to the plans and resend.
Siteplan:
1.Revise to show a 20’ setback from both Ft. Lowell & Country Club.
2.Show dimensions of the SVTs.
3.Show the dimensions for the frontage along Country Club Rd.
4.Show & call out for a bollard at the SE corner of sign (parking lot corner)
Drawing:
1.The 10’ OAH needs to be shown as measured from the top of the curb at both streets.( Ft. Low/ CClub) Not from the base of sign as indicated in drawing.
Our survey shows the sign is 1.5’ too tall.
Options are to
A. Graded/dropped the earth at the sign site by 1.5’
OR
B. Modify/shorten the pole cover/skirting on the sign, so that the OAH of sign is only 8’6” tall.
Footing Engineering:
1.Need to show ASA/Schneider stamp.

We have determined that a PDMR will not be required.