Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: SIGN SITE REVIEW
Permit Number - T14OT01125
Inspection Description - SIGN SITE REVIEW
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2014 | SIGN SITE REVIEW | Correction Required | Minimum setback for pole sign: Thirty (30) feet from curb to leading edge of sign. Indicate the set back and location of new sign on site plan Provide the following to continue review: Additional legible scaled site plan Engineered plans and specifications: The following signs shall require engineered plans and calculations sealed by an engineer and/or architect registered in the State of Arizona: Detached or freeway signs when the area of the sign or the aggregate area of all signs on the sign structure, including the pylon and/or pole cover, exceeds sixty (60) square feet. Provide engineering plans |
|
09/11/2014 | SIGN SITE REVIEW | Correction Required | Sign indicated on application would be considered a new freestanding pole sign verify the sign meets the following criteria: Freestanding pole sign requirements: 1. Maximum faces: Two (2) per sign. 2. Maximum area: Seventy-two (72) square feet per face. 3. Maximum height: Twelve (12) feet. 4. Minimum setback: Thirty (30) feet from curb to leading edge of sign. 5. Pole cover: The sign structure configuration must be equipped with pole covers or architectural embellishments that hide or conceal all structural components or braces (such as pipes, angles, iron, cables, internal back framing, bracing, etc.). Minimum requirement is eighteen (18) inches by six (6) inches. The pole cover or architectural embellishment shall require a plan check for construction specifications in accordance with applicable technical codes. 6. When allowed: Allowed only when there is a minimum of two hundred twenty- five (225) feet of street frontage, or one hundred twenty-five (125) feet of street frontage and four (4) or more business addresses. 7. Maximum number: Only one (1) freestanding pole sign allowed per street frontage per premises. 8. Allowed only in the general business district; industrial district; medical-business- industrial park district; park district and planned area development district. Provide the following to continue review: FREESTANDING SIGNS ARE REQUIRED TO INCLUDE WITH SUBMITTALS: A scaled site plan indicating street frontage, property lines, sight visibility triangles, proposed and existing rights-of-way, location of sign on property and relationship of proposed sign to ingress and egress points. Previously approved site plan can be found @ http://www.tucsonaz.gov/PRO/pro/devactionsrch.jsp Engineered plans and specifications. The following signs shall require engineered plans and calculations sealed by an engineer and/or architect registered in the State of Arizona: 1. Detached or freeway signs when the area of the sign or the aggregate area of all signs on the sign structure, including the pylon and/or pole cover, exceeds sixty (60) square feet. |