Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T14OT00948

Parcel: 99999999A

Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T14OT00948

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
10/30/2014 SIGN SITE REVIEW Approved
09/09/2014 SIGN SITE REVIEW Correction Required T14OT00948

D.ROBERTS & B. WIESE

SIGN WILL BE MORE THAN 40' FROM ROAD PER PLAN. SIGN LOCATION NOT MARKED. LIKELY LOCATION OF SIGN BASED ON PLAN HAS GRADE DIFFERENCE OF 1.3' AT POSSIBLE BASE TO LOWEST FINISHED SURFACE (DRIVEWAY) WITHIN 20 FEET. PLAN SHOWS SETBACK FROM BIKE LANE. SETBACK MEASUREMENT IN FIELD TAKEN FROM CURB MATCHES SETBACK NUMBER ON PLAN FROM BIKE LANE.

1) REVISE PLAN TO SHOW SETBACK FROM CURB NOT BIKE LANE.
2) REVISE PERMIT APPLICATION TO MATCH SETBACK ON PLAN.
3) REVISE ELEV VIEW TO SHOW GRADE AT SIGN BASE, GRADE AT LOWEST POINT WITHIN 20', AND 1.3' DIFFERENCE BETWEEN THEM.
4) MEET WITH ANDREW CONNOR TO DISCUSS HOW LANDSCAPE CONDITIONS OF VARIANCE CASE SHOULD BE SHOWN ON PLAN

RESUBMIT REVISED DRAWINGS TO DSD_SIGNS@TUCSONAZ.GOV AND INDICATE IS A RESUBMITTAL IN SUBJECT LINE WITH PERMIT NUMBER AND PROJECT NAME.
09/05/2014 SIGN SITE REVIEW Continued Sent for field inspection.
08/26/2014 SIGN SITE REVIEW Correction Required PERMIT T14OT00948
FOR: (1) ILLUM D.F. MONUMENT SIGN (on Golf Links side of site)
AT: 10142 E Golf Links Road, Sorrento Square
NOTE: prior variance case T10SA00193
Reviewer: Heather Thrall, Eric Newcomb
8/21 & 8/22 (inspection results)

THE FOLLOWING CODES APPLY TO THIS REVIEW: OUTDOOR LIGHTING CODE (OLC), UNIFIED DEVELOPMENT CODE (UDC), INTERNATIONAL BUILDING CODE (IBC), SIGN CODE (SC), NATIONAL ELECTRIC CODE (NEC)

STRUCTURAL: (Eric Newcomb)

1) On-site welding notation on sign install diagram requires a special inspection. Have engineer fill out special inspection certificate, noting "field welding" inspection, designating qualified inspector. Special inspector certificate must be approved by structural review prior to permit release. Certificate must be affirmed by inspector/engineer that work has been finished for the permit to be finaled. Link to certificate is here: http://pdsd.tucsonaz.gov/files/pdsd/forms/Special_Inspection_Certificate_1-9-14.pdf

SIGN CODE:

2) Acknowledged proposed sign location is shown in red on the site plan. Records will scan this document in black/white. It is noted the proposed sign is shown on an overlay of the development plan for the shopping center, and there are other spots - in black/white - that show sign locations on this plan that have not been approved by the signs division. Please mark out these potential sign locations (labeled with #5's on the drawing) so as to maintain an accurate record of the sign being reviewed under this permit and for inspections purposes and ensure no confusion.
3) Setback noted on application does not match setback noted on site plan, can be corrected in person at permit pick up.
4) Variance case T10SA00193, approval with condition #4 notes a 70% landscape ground cover in a 10 foot radius around the base of all freestanding signs along Golf Links frontage. Meet with Andrew Connor in the Landscape Division to determine what information should be demonstrated on either the sign plan or the landscape plan for the development (or both?) to show the variance condition of approval can be met to install the sign. (Andrew.Connor@tucsonaz or 847-4950)
5) SETBACK INSPECTION: 8/22, Inspector Ron Le Donne reports unable to examine sign setbacks - sign location is not marked and the driveway entrance is incomplete. (As construction progresses on site, email request for pre-site sign review reinspection.)
6) HEIGHT INSPECTION: 8/22, Inspector Ron Le Donne reports unable to examine sign height/grade check due to sign location un-marked and construction on site. (As construction progresses on site, email request for pre-site sign review reinspection.)

SEND RESUBMITTALS TO DSD_SIGNS@TUCSONAZ.GOV IN THE SUBJECT HEADING "RESUBMITTAL FOR PERMIT T14OT00948"
08/26/2014 SIGN SITE REVIEW Continued Contractor representative resubmitted changes by email. New sign location at different driveway off Golf Links proposed instead. Staff to review variance conditions, review changes and send for field inspection.
08/26/2014 SIGN SITE REVIEW Continued CONTRACTOR REP RESUBMITTED PLANS WITH NEW SIGN LOCATION (EAST DRIVEWAY NEAR EXISTING QUIKTRIP). REVIEW CONTINUES. WILL NEED TO SEND BACK OUT FOR SETBACK/HEIGHT CHECK AND HAVE CONTRACTOR CONSULT LANDSCAPE REVIEWER FOR HOW TO BEST DEMONSTRATE COMPLIANCE WITH SIGN VARIANCE CONDITIONS.
08/25/2014 SIGN SITE REVIEW Denied UNABLE TO CHECK SET BACK AND GRADE. UNMARKED AND GRADED.
08/22/2014 SIGN SITE REVIEW Denied Sign location not marked
Driveway entrance incomplete
Unable to determine setback/height proposal would be within code due to site construction at this time.
08/21/2014 SIGN SITE REVIEW Continued SENT OUT FOR SETBACK AND GRADE/HEIGHT CHECK TO FINISH REVIEW.