Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T14OT00947

Parcel: 11615088L

Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T14OT00947

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
09/10/2014 SIGN SITE REVIEW Approved
08/21/2014 SIGN SITE REVIEW Continued NO ISSUES WITH PROPOSED 30' SETBACK, NO ISSUES WITH PROPOSED HEIGHT/GRADE DIFFERENTIAL.

ADDRESS REVIEW COMMENTS TO RELEASE PERMIT.
08/21/2014 SIGN SITE REVIEW Continued PERMIT T14OT00947
FOR: (1) NEW ILLUM MONUMENT & (1) ILLUM TRAFFIC DIRECTIONAL
AT: 1601 W SAINT MARY'S ROAD, SAINT MARY'S HOSPITAL
REVIEWER: Heather Thrall/Glenn Moyer/Eric Newcomb

THE FOLLOWING CODES APPLY TO THIS REVIEW: OUTDOOR LIGHTING CODE (OLC), UNIFIED DEVELOPMENT CODE (UDC), INTERNATIONAL BUILDING CODE (IBC), SIGN CODE (SC), NATIONAL ELECTRIC CODE (NEC)


STRUCTURAL:
1) Per Structural Reviewer, on site welding noted on monument diagram. Such requires a special inspection for "field welding". Engineer to stamp certificate, identify inspection required and name qualified inspector to perform inspection. Special inspection certificate is required to be reviewed by structural reviewer prior to sign permit release. Certificate is found at this link: http://pdsd.tucsonaz.gov/files/pdsd/forms/Special_Inspection_Certificate_1-9-14.pdf

ELECTRICAL:
2) Per NEC 600, show location of means of disconnect for traffic directional sign.

U.D.C.:
3) Per UDC Section 7.4.6.F.2.b, regarding traffic directional and monument positioning within central driveway island, demonstrate the following in diagram format:
A) the width across the driveway island as measured from outer curb faces
B) show a 2' minimum setback can be met from closest edge of sign(s) to face of curb.

ENGINEERING: (Loren Makus)
4) St. Mary's Road is at the current/future maximum 100' width. Please remove reference to the 75' "future ½ ROW and show SVT's based upon current right of way, dimensioning short stem end of the SVT as well.

SIGN CODE:

5 Per 3-32, 3-83 and sign Variance case S-94-4 - Sign area calculations depend upon street frontages. None are noted on the site plan cover sheet submitted for the review. Please provide frontage dimensions for the street property lines along St. Mary's, Silverbell and Anklam. (Staff understands this site has a very large and varying amount of site plans over years of construction phases and is researching for a better site plan to assist the contractor.) Acknowledged this site is surrounded by three streets and is allowed 3 to 1 ratio per variance.
6 Per variance case S-94-4 Notice of Decision conditions, the maximum size of a freestanding sign is 40 square feet along Silverbell. The submitted sign is 50 square feet sign area. Revise.

(insp. 8/21/14 by D. Roberts concludes no issues with setback or height/grade difference)
08/19/2014 SIGN SITE REVIEW Continued Sign Contractor rep provided inventory of existing freestanding signs on 8/15/14. project being sent out for setback/grade check on 8/20 to finish review.
08/12/2014 SIGN SITE REVIEW Continued Permit T14OT00947
For: (1) new illum monument sign
AT: St. Mary's Hospital, 1601 W Saint Mary's Road
Location: off Silverbell side of site

Reviewer: Heather.Thrall@tucsonaz.gov

Date: 8/12/14


Courtesy update to the contractor. Staff located a sign variance case for this property, case S-94-4. This variance case, related to requirements of signage on development subject to the Scenic Route criteria, limits the number of freestanding signs at this location. Provide a photographic sign inventory of all freestanding signs (not including traffic directionals). Show existing freestanding sign locations on a map of the property for further review. Identify any sign removals under this proposal.

Note: staff will continue review of the proposed sign while waiting for the freestanding sign inventory.