Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T14OT00819

Parcel: 133243720


Addresses:

250 N PANTANO RD


Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T14OT00819

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
09/16/2014 SIGN SITE REVIEW Approved
07/02/2014 SIGN SITE REVIEW Correction Required Permit T14OT00819
Reviewer: Heather.Thrall@tucsonaz.gov
Date: july 1, 2014
For: new illum wall signs + change copy on monument

The following codes apply to this review:

THE FOLLOWING CODES APPLY TO THIS REVIEW: OUTDOOR LIGHTING CODE (OLC), UNIFIED DEVELOPMENT CODE (UDC), INTERNATIONAL BUILDING CODE (IBC), SIGN CODE (SC), NATIONAL ELECTRIC CODE (NEC)

1) PER O.L.C. 403.5 Outdoor Lighting Controls. 403.5.1 The means of controlling the specific "off" curfew shall be by a 24 hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. *** Provide notation timer will be provided.***
2) Per SC 3-18, provide either notation or attachment information for the installation of the panel signs, and clarify on diagram for raceway signs what type of wall surface is to be penetrated (i.e. frame/stucco or CMU?)
3) Per SC3-18 dimension length of "sign A"
4) Proposal shows one tenant to use 50 sqft of sign area on a monument. Per 3-77 General Business District - sign area on a monument for a sole tenant is allowed up to 31.9 sqft, max 32 sqft if self-contained premise. This tenant space is one building within a shopping center and does not appear to be a self-contained premise. Tenant panel on monument sign should be revised to 31.99 sqft or less.