Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T14OT00794

Parcel: 130144510


Addresses:

1305 S ALVERNON WY


Inspection Status: Continued

Inspection History: SIGN SITE REVIEW

Permit Number - T14OT00794

Inspection Description - SIGN SITE REVIEW

Inspection Status - Continued

Date Description Inspector Results Comments
08/04/2014 SIGN SITE REVIEW Continued BOTH WALL SIGNS HAVE BEEN INSTALLED, NO INSPECTIONS CALLED IN
07/02/2014 SIGN SITE REVIEW Partial Approval All review comments 1-5 addressed prior. Only comment remaining is #6, to provide a timer. Emailed contractor with this information.

PERMIT T14OT00794
FOR: (2) NEW ILLUM. WALL SIGNS @51.4 sqft Each
AT: 1305 S. ALVERNON WAY, PROGRESSIVE INSURANCE (NEW CONSTR.)
REVIEWER: HEATHER.THRALL@TUCSONAZ.GOV
07/02/14

PARTIAL APPROVAL GRANTED: UNDERSTOOD SIGNAGE WILL MEET CODE, REVISE DRAWINGS TO COMMENTS BELOW FOR ACCURATE CALCULATIONS/RECORDS.

THE FOLLOWING CODES APPLY TO THIS REVIEW: NATIONAL ELECTRICAL CODE (NEC), OUTDOOR LIGHTING CODE (OLC), INTERNATIONAL BUILDING CODE (IBC), UNIFIED DEVELOPMENT CODE (UDC) AND SIGN CODE (SC).


1) Per O.L.C. 403.5.1 The means of controlling the specific "off" curfew shall be by a 24 hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. ***Provide notation a timer shall be provided. ***

2) CONTACT REVIEWER IF QUESTIONS. YOU MAY EMAIL CHANGES TO HEATHER.THRALL@TUCSONAZ.GOV PLEASE SEND DRAWINGS IN PDF FORMAT TO BE ABLE TO PRINT OUT TO 11X17 SIZE.
07/02/2014 SIGN SITE REVIEW Approved contractor emailed revised drawing.
06/24/2014 SIGN SITE REVIEW Partial Approval PERMIT T14OT00794
FOR: (2) NEW ILLUM. WALL SIGNS @51.4 sqft Each
AT: 1305 S. ALVERNON WAY, PROGRESSIVE INSURANCE (NEW CONSTR.)
REVIEWER: HEATHER.THRALL@TUCSONAZ.GOV
6/24/14

PARTIAL APPROVAL GRANTED: UNDERSTOOD SIGNAGE WILL MEET CODE, REVISE DRAWINGS TO COMMENTS BELOW FOR ACCURATE CALCULATIONS/RECORDS.

THE FOLLOWING CODES APPLY TO THIS REVIEW: NATIONAL ELECTRICAL CODE (NEC), OUTDOOR LIGHTING CODE (OLC), INTERNATIONAL BUILDING CODE (IBC), UNIFIED DEVELOPMENT CODE (UDC) AND SIGN CODE (SC).


1) Per S.C. 3-18/3-33, provide street frontage dimensions on the application and on sign location map for sign area calculation records. (ACKNOWLEDGED: Development Package sheet provided in packet shows building wall length along Juarez Street will be 135.6 linear feet. You may use this number or length of lot line, as this is a single tenant on this lot. It is clear to reviewer total sign area proposed at approximately 102 sqft is fully within sign area allowance of 3 sqft sign area per each 1 linear foot of street frontage whether contractor uses building wall length or using greater length of property line, and further known the wall signs will, by far, not cover more than 30% of any building wall.)

2) Per SC 3-18, staff noted discrepancy in size of sign between application (51.04 sqft of sign area) and drawing sheet 14 (53.12 sqft). Revise drawing.

3) Per SC 3-18, staff noted discrepancy in height off ground between drawing and application for sign on the west elevation. Revise application.

4) Per SC 3-18, provide mounting bracket/fastener details (size, type, number of typical penetrations per letter) and type of wall penetrated.

5) Per N.E.C. 600, clearly call out the means of disconnect by identifying the shut off switch and where located.

6) Per O.L.C. 403.5.1 The means of controlling the specific "off" curfew shall be by a 24 hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. Provide notation a timer shall be provided.

7) CONTACT REVIEWER IF QUESTIONS. YOU MAY EMAIL CHANGES TO HEATHER.THRALL@TUCSONAZ.GOV PLEASE SEND DRAWINGS IN PDF FORMAT TO BE ABLE TO PRINT OUT TO 11X17 SIZE.
06/16/2014 SIGN SITE REVIEW Correction Required CONTRACTOR CONTACTED - SEND LARGER PRINTS FOR REVIEW.