Permit: T14OT00791

Parcel: 11504520B


Addresses:

1011 N TYNDALL AV


Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T14OT00791

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
07/30/2014 SIGN SITE REVIEW Approved Eric Newcomb & Heather Thrall met with Art from Trademark Visual on 7/30/14. Plans and engineering revised - approved for permit release. Special inspection required for sign attachment.
07/25/2014 SIGN SITE REVIEW Correction Required Permit T14OT00791
At: 1011 N Tyndall Av
For: The Hub - 1 new illum wall sign @ 180 sqft on N. elev
REVIEWER: HEATHER.THRALL@TUCSONAZ.GOV & ERIC.NEWCOMB@TUCSONAZ.GOV
2ND REVIEW: JULY 25, 2014

THE FOLLOWING CODES APPLY TO THIS REVIEW: OUTDOOR LIGHTING CODE (OLC), UNIFIED DEVELOPMENT CODE (UDC), MAIN GATE URBAN OVERLAY (MG-UOD), INTERNATIONAL BUILDING CODE (IBC), SIGN CODE (SC), NATIONAL ELECTRIC CODE (NEC)

REVIEWERS: Heather Thrall & Eric Newcomb

***NOTE, last submittal 7/7/14 by email included 2 different sets of plans and a special inspection certificate. Differences in color, drawing date and location map were noted. Staff emailed contractor for clarification on which set to review and the need for revised engineering. Review proceeded without response from contractor with both sets being examined. ***

1) Design Review Committee (DRC) for Main Gate Urban Overlay District approved the proposed signage on Monday, June 9, 2014. ***COMMENT REMAINS FROM LAST REVIEW: Provide notation on plans "signage shall be installed per applicable City of Tucson codes and per criteria approved by Main Gate -Urban Overlay District D.R.C. on June 9, 2014."***

2) Per SC 3-77, Project is in General Business District of the Sign Code. On sign location sheet, provide street frontage along Tyndall Ave for the site and to show for records the total allowed sign area is based upon, and within allowance of, 3 x street frontage. Note, Development Package dp12-0816, sheet A001 lists the street frontage along 1st street as 183.42 linear feet, and along Tyndall Av the frontage is 173'6". (Understood total sign area proposed and listed per prior permit for an undercanopy sign are fully within total sign area allowance for the site thus far, information requested on plans is for records of code compliance). *** COMMENT REMAINS FROM LAST REVIEW: Revise 1st Street frontage***


3) Per IBC (Reviewer Eric Newcomb), sheet 9 of engineering calculations indicates 1 anchor, clarify if this number is the number of anchors per letter? Appears insufficient. (Does number of anchors mean number per letter? - Clarify) ***COMMENT REMAINS FROM LAST REVIEW - NO REVISED ENGINEERING WAS SUBMITTED WITH THE PLANS. PROVIDE AND ENSURE CALCULATIONS ARE SEALED BY ARCHITECT OR ENGINEER.***

4) Per IBC, provide diagram that shows the number of fasteners and mounting clips per letter and ensure engineering calcs match. ***COMMENT REMAINS FROM LAST REVIEW***


5) Per IBC, provide detail diagram that shows how the mounting clips actually fasten to the sign letters. ***COMMENT REMAINS FROM LAST REVIEW***

6) Per IBC, both the engineering calculations and the drawings must be stamped by the engineer of record. ***COMMENT REMAINS FROM LAST REVIEW*** NOTED THAT ONLY 1 SET OF THE 2 SETS OF PLANS EMAILED ON 7/7 WAS SEALED BY ENGINEER.


7) Further review comments may be forthcoming, depending upon responses provided.
Email revisions to the sign code reviewer to route through the other divisions of the department. Her email address is Heather.Thrall@tucsonaz.gov
07/15/2014 SIGN SITE REVIEW Continued STAFF EMAILED CONTRACTOR FOR CLARIFICATION - NEED NEW ENGINEERING CALCS AND EVERYTHING STAMPED BY ENGINEER
07/07/2014 SIGN SITE REVIEW Continued CONTRACTOR EMAILED REVISED SET OF DRAWINGS AND NEW SPECIAL INSPECTION CERT.
06/25/2014 SIGN SITE REVIEW Correction Required Permit T14OT00791
At: 1011 N Tyndall Av
For: The Hub - 1 new illum wall sign @ 180 sqft on N. elev

THE FOLLOWING CODES APPLY TO THIS REVIEW: OUTDOOR LIGHTING CODE (OLC), UNIFIED DEVELOPMENT CODE (UDC), MAIN GATE URBAN OVERLAY (MG-UOD), INTERNATIONAL BUILDING CODE (IBC), SIGN CODE (SC), NATIONAL ELECTRIC CODE (NEC)

REVIEWERS: Heather Thrall & Eric Newcomb - June 25, 2014 (upon receipt of Special Inspection Certificate.)

1) Acknowledged the Design Review Committee (DRC) for the Main Gate Urban Overlay District approved the proposed signage on Monday, June 9, 2014. Provide notation on plans "signage shall be installed per applicable City of Tucson codes and per criteria approved by Main Gate -Urban Overlay District D.R.C. on June 9, 2014."
2) Per SC 3-77, Project is within General Business District of the Sign Code. On sign location sheet, provide frontage along Park Avenue for the property and to show for records the total allowed sign area is based upon, and within allowance of, 3 x street frontage. Note, Development Package dp12-0816, sheet A001 lists the street frontage along 1st street as 183.42 linear feet, and along Tyndall Av the frontage is 173'6". (Understood total sign area proposed and listed per prior permit for an undercanopy sign are fully within total sign area allowance for the site thus far, information requested on plans is for records of code compliance).
3) Per NEC 600, Note total number of volts, amps, circuits.
4) Per OLC 403.5 Outdoor Lighting Controls. 403.5.1. The means of controlling the specific "off" curfew shall be by a 24 hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. *Provide notation a timer shall be provided*.
5) Per IBC (Reviewer Eric Newcomb), sheet 9 of engineering calculations indicates 1 anchor, clarify if this number is the number of anchors per letter???? Appears insufficient. (Does number of anchors mean number per letter? - Clarify)
6) Per IBC, provide diagram that shows the number of fasteners and mounting clips per letter and ensure engineering calcs match.
7) Per IBC, provide detail diagram that shows how the mounting clips actually fasten to the sign letters.
8) Per IBC, both the engineering calculations and the drawings must be stamped by the engineer of record - John C. Schneider (as noted on special inspection certificate).
9) Per SC 3-23, Special inspection for this sign is required. Acknowledged the special inspection sheet has been turned in as of 6/24/14. However, name listed on special inspection certificate (John C Schneider) is not a listed and qualified special inspector for Epoxy Expansion Anchors per the approved list on file with Oro Valley/PC/COT listing for International Code Council certified inspectors. Have engineer assign an ICC approved inspector and send in a new special certificate with this information.
10) Note that further review comments may be forthcoming, depending upon the responses provided.
11) Email revisions to the sign code reviewer to route through the other divisions of the department. Her email address is Heather.Thrall@tucsonaz.gov
06/16/2014 SIGN SITE REVIEW Continued CONTRACTOR CONTACTED TO PROVIDE SPECIAL INSPECTION CERTIFICATE. UPON RECEIPT OF THAT CERTIFICATE, STRUCTURAL REVIEW CAN BE COMPLETED.