Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T14OT00567

Parcel: 13316020P


Addresses:

6501 E GRANT RD

Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Date Description Inspector Results Comments
08/21/2014 SIGN SITE REVIEW Approved
05/09/2014 SIGN SITE REVIEW Correction Required RE: VERIZON SIGN REVIEW
FOR: 6501 E GRANT RD
PERMIT: T14OT00567
APPLICABLE CODE: SIGN CODE(SC)/CHAPTER 3 TUCSON CODE
REVIEWER: HEATHER.THRALL@TUCSONAZ.GOV
DATE: 5/9/14
EMAIL REVISIONS TO REVIEWER:



THIS SUBMITTAL IS PRECURSORY REVIEW AND FURTHER REVIEW COMMENTS MAY BE FORTHCOMING, DEPENDING UPON RESUBMITTED INFORMATION. UNTIL BUILDING PLAN IS APPROVED, SIGN PROJECT CANNOT BE FULLY REVIEWED - AS INFO IS NEEDED OFF NEW BUILDING PLAN. UNTIL BUILDING PERMIT IS ISSUED, NO SIGN PERMITS WILL BE ISSUED.

NOTE: THE FOLLOWING IS PRECURSORY REVIEW AS A COURTESY TO THE SIGN CONTRACTOR TO PROVIDE ACCURATE MATERIALS FOR RESUBMITTAL.

1) PER S.C. 3-18, ON APPLICATION, LIST STREET FRONTAGE TO MATCH DRAWINGS FOR GRANT ROAD FRONTAGE

2) PER SC 3-77: APPLICATION AND DRAWINGS EXCEED ALLOWED SIGN AREA. THESE ARE SEPARATE SIGNS NOT ONE SIGN, BREAK DOWN SIGN AREA DIMENSIONS AND PROVIDE NEW APPLICATION MATERIALS TO REFLECT 2 SIGNS EACH ELEVATION.

3) PER SC 3-77: MAX SIGN AREA IS 120 TOTAL, ACCORDING TO A FRONTAGE OF 40' ALONG GRANT IN SUBMITTED ELEVATION VIEW. REVISE PLANS AND RESUBMIT.

4) NOTE - BUILDING PERMIT REQUERED FOR AWNINGS SHOWN IN THE DRAWING BELOW WALL SIGNAGE.

5) PROVIDE COPY OF APPROVED DEVELOPMENT PACKAGE AND BUILDING ELEVATIONS UPON RESUBMITTAL. PLAN NUMBERS ARE DP13-0236 T14CM01461 AND HAVE NOT BEEN APPROVED, ONLY GONE THROUGH 2ND REVIEW.