Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/28/2014 |
MECHANICAL - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* |
| 03/21/2014 |
MECHANICAL - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* |
| 03/21/2014 |
MECHANICAL - INTERMEDIATE |
|
Partial Approval |
WATER HEATER VENT CONNECTOR NEEDS A 3X4 REDUCER. PROVIDE AN OVERFLOW SENSOR IN SECONDARY DRAIN. PROVIDE HOSE CLAMPS AT PUMP HOSE CONNECTIONS. USE REDWOOD BLOCKS TO SUPPORT DRAIN LINE. USE APPROVED TAPE FOR LINESET. PROVIDE A ROOF JACK AT ELEC PENETRATION. PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE ON ROOF. PROVIDE DOUBLE VENT THROUGH THE ROOF WITH AN APPROVED CAP. |
| 03/20/2014 |
MECHANICAL - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |