12/12/2014 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, MET WITH TFD INVESTIGATOR WAYNE CUMMINGS WHO STATED UPON ARRIVAL TFD FOUND FLAMES COMING OUT OF THE GARAGE UNDER THE GARAGE DOOR. GARAGE WAS FULL OF PERSONAL BELONGINGS BUT EASY TO NAVIGATE AROUND THE GARAGE. TFD HAD CUT ALL POWER TO THE PROPERTY STRUCTURE, FLAME PATTERN FROM THE GARAGE FIRE SHOWED FIRE STARTING AT A ADDED LIGHT AND SWITCH CIRCUIT, BURNED A FEW CONTENTS AND A SMALL SECTION OF THE GARAGE DOOR INSIDE THE GARAGE AT WHICH POINT TFD WAS ABLE TO PUT THE FIRE OUT.
** FURTHER INSPECTION OF THE ELECTRICAL SYSTEM AND MAIN SERVICE PANEL REVEALED MULTIPLE ADDED CIRCUITS, SUB PANELS AND JUNCTION BOXES. DEFECTIVE WIRING WAS FOUND IN A JUNCTION BOX THAT LED TO THE LIGHT AND SWITCH THAT BURNED. MAIN SERVICE PANEL WAS OVERLOADED.
* NOV WAS ISSUED TO THE HOMEOWNER ASKING FOR A LICENSED ELECTRICAL CONTRACTR TO TO EVALUATE THE MAIN SERVICE PANEL AND ADDED CIRCUITS AND UPGRADE OF MAKE ALL NECESSARY REPAIRS. OWNER DID START CALLING ELECTRICAL CONTRACTORS WHILE ON SITE.