Case: T14DV09797

Parcel: 11107146C


Addresses:

2710 N EDITH BL #B

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
12/09/2014 INSP - INITIAL CODE ENFORCMENT Approved CHECKED ROOF, FOUND DRAIN HOLES ON THE ROOF ARE BLOCKED BY LEAVES, PINE NEEDLES AND DIRT CAUSING WATER TO POND ON THE ROOF. A FEW SMALL CRACKS IN THE ROOFING MATERIAL IS ALLOWING THE WATER TO SEEP INTO THE BUILDING STRUCTURE. CALLED OWNER AND DISCUSSED FINDING AND WHAT WILL NEED TO BE DONE TO ADDRESS THE ISSUES. ALSO MENTIONED THE TERMIT DAMAGE FOUND ON THE EXTERIOR OF THE BUILDING.
12/08/2014 INSP - INITIAL CODE ENFORCMENT Approved COMPLAINT: ROOF LEAKING & TERMITES.

INSPECTED INTERIOR UNIT #B APPEARS IN THE BACK BEDROOM THERE WAS SOME WATER DAMAGE TO THE CEILING. THE LAUNDRY ROOM LOCATED OUTSIDE AT THE BACK END OF THE UNIT THE WATER DAMAGE/MOISTURE IS LOCATED IN THE AREA WHERE THE WASHING MACHINES SIT. APPROX 2FT X 2FT AREA ON THE CEILING IS MOLDED AND ON THE WALL THE PAINT IS SAGGING AND MOLDED. OUTSIDE THE LAUNDRY ROOM AT THE BASE OF THE DOOR FRAME SHOWS SIGNS OF TERMIT DAMAGE. OCCUPANT STATED SHE DID NOT SEE OR FIND ANY TERMITS OR ANY OTHER TYPE OF PEST INSIDE THE UNIT.