Case: T14DV00349

Parcel: 120052170


Addresses:

4507 S 14TH AV

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
01/17/2014 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL FROM TFD; THERE WAS MINOR DAMAGE TO A STORAGE SHED LOCATED IN THE BACKYARD. THE FIRE DAMAGE WAS THE ROOF OSB SHEATHING ABOUT A 12 INCH DIAMETER AREA. THERE ROOF COVERING IS CORRUGATED STEEL PANELS WHICH ARE UNDAMAGED. THIS SHED WAS BUILT IN 1970 AND IS UNDER 200 SQUARE FEET. THE SHED IS BEING POWERED BY AN ILLEGAL CIRCUIT. THE CIRCUIT WAS TURNED OFF AT THE MAIN DISCONNECT WHICH HAS OTHER VIOLATIONS. THE 15 AMP BREAKER HAS TWO CONDUCTORS IN THE TERMINAL. THE PANEL HAS UNUSED OPENINGS. THE EXTERIOR PVC CONDUIT IS BROKEN.