Permit: T14CM08311

Parcel: 205942340

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T14CM08311

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/20/2015 FRAMING Approved IVRS - Inspection :*
10/19/2015 FRAMING Denied 1. DWV SYSTEM IS LEAKING, CHECK ENTIRE SANITARY SYSTEM.
2. P-TAPE IS NOT APPROVED FOR HANGING AND STRAPING. PROVIDE BLOCKING ANSD STRAP EVERY 4'-00"
3. SHALL SEAL ALL PENETRATIONS THROUGH STUCCO MESH. EAST WALL.
4. SHALL SEAL ENTIRE BOTTOM PLATE 1ST FLOOR
5. PROVIDE FIRE STOP ON TOP PLATE PENETRATIONS
6. END OF INSPECTION. PLEASE WALK ENTIRE JOB PRIOR TO CALLING IN FOR INSPECTION
7. STRAP GAS LINE THROUGHOUT SYSTEM.