Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T14CM08311
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/20/2015 | FRAMING | Approved | IVRS - Inspection :* | |
10/19/2015 | FRAMING | Denied | 1. DWV SYSTEM IS LEAKING, CHECK ENTIRE SANITARY SYSTEM. 2. P-TAPE IS NOT APPROVED FOR HANGING AND STRAPING. PROVIDE BLOCKING ANSD STRAP EVERY 4'-00" 3. SHALL SEAL ALL PENETRATIONS THROUGH STUCCO MESH. EAST WALL. 4. SHALL SEAL ENTIRE BOTTOM PLATE 1ST FLOOR 5. PROVIDE FIRE STOP ON TOP PLATE PENETRATIONS 6. END OF INSPECTION. PLEASE WALK ENTIRE JOB PRIOR TO CALLING IN FOR INSPECTION 7. STRAP GAS LINE THROUGHOUT SYSTEM. |