Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T14CM08203
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/05/2015 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
12/24/2014 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
12/24/2014 | PLUMBING - INTERMEDIATE | Not ready for Inspection | CANCELED BY RUDY | |
12/23/2014 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
12/23/2014 | PLUMBING - INTERMEDIATE | Denied | FS VENT SHALL RISE VERTICALLY TO A POINT ABOVE FLOOD LEVEL. INTERCEPTOR REQUIRES A VENT. OUTLET CONNECTIONS SHALL BE SIZED PER MANUFACTURERS INSTALL INSTRUCTIONS. FLOW CONTROL FITTING REQUIRES ACCESS. ALSO, PROVIDE INSTALL INSTRUCTIONS. EXPOSE OUTLET PIPING. REDLINE NEW HAND SINK CONN. SUPPORT TRAP ARMS. | |
12/18/2014 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
12/18/2014 | PLUMBING - INTERMEDIATE | Partial Approval | NEW GT REQ INSPECTION. FLOW CONT (?), VENT, ETC. HAND SINK REQUIRES A DIRECT CONN |