Permit: T14CM08203

Parcel: 11451216G

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/05/2015 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
12/24/2014 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
12/24/2014 PLUMBING - INTERMEDIATE Not ready for Inspection CANCELED BY RUDY
12/23/2014 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/23/2014 PLUMBING - INTERMEDIATE Denied FS VENT SHALL RISE VERTICALLY TO A POINT ABOVE FLOOD LEVEL. INTERCEPTOR REQUIRES A VENT. OUTLET CONNECTIONS SHALL BE SIZED PER MANUFACTURERS INSTALL INSTRUCTIONS. FLOW CONTROL FITTING REQUIRES ACCESS. ALSO, PROVIDE INSTALL INSTRUCTIONS. EXPOSE OUTLET PIPING. REDLINE NEW HAND SINK CONN. SUPPORT TRAP ARMS.
12/18/2014 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
12/18/2014 PLUMBING - INTERMEDIATE Partial Approval NEW GT REQ INSPECTION. FLOW CONT (?), VENT, ETC. HAND SINK REQUIRES A DIRECT CONN