Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2014 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 12/11/2014 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 12/11/2014 | ELECTRIC - RECONNECT | Denied | UNABLE TO REMOVE HOMEMADE DEAD FRONT TO INSPECT INSIDE PANEL | |
| 11/28/2014 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/28/2014 | ELECTRIC - RECONNECT | Denied | 1. PROVIDE APPROVED DEAD FRONT AT SERVICE PANEL 2. WHITE WIRE NOT TO BE USED AS A HOT LEG 3. THIS IS AN UNDERGROUND SYSTEM, ALL OUTLETS TO BE UNDERGROUND (TWO PRONG) OR GFCI PROTECTED 4. WATER HEATER T & P NOT TO BE RUN ITH WASHING MACHINE HOSE 5. SMOKE ALARM REQUIRED IN HALLWAY LOADING TO BEDROOMS |
|
| 11/26/2014 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : There is no access to the site.| 920* |
|
| 11/26/2014 | ELECTRIC - RECONNECT | Denied | CALLED 406-1493 AT 7:54 AND LEFT MSG THAT WOULD BE AT ADDRESS BETWEEN 8:30-9:30 WITH MY PHONE # UNABLE TO ACCESS PLEASE CALL TO RE-SCHEDULE |