Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T14CM07163

Parcel: 138213670


Addresses:

7126 S CORONA PL

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
01/06/2015 ROOF NAILING Approved IVRS - Inspection :*
12/19/2014 ROOF NAILING Partial Approval IVRS - Inspection :*
12/19/2014 ROOF NAILING Partial Approval 1. COMPLY WITH PREVIOUS NOTES 3 & 5
2. AS BUILT TO 8/5 OR BUILD TO PLAN
3. PROVIDE ?? 6" OC @ GABLE END TOP CORD PER ENGINEERED FIX (?)
4. MISSING RAT RUN 4CM 28 MECHANICAL TRUSSES
12/10/2014 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/10/2014 ROOF NAILING Denied 1. COMPLY WITH PREVIOUS
2. PROVIDE STAMPED APPROVED TRUSS CALCS TO MATCH
3. PER DETAIL 3/2.1 OSB TO REACH TOP/TOP PLATE ON ALL BRACED PANELS
4. PROVIDE DIAPHRAM NAILING PER DETAIL 6/5 8D 6" OK
5. SUBMIT AS BUILT TO DETAILS 8/5 & 15/5 OR BUILD TO PLAN
12/08/2014 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/08/2014 ROOF NAILING Denied - LATERAL BRACE RAFTERS PER RAFTER SPECS
- NAIL BIRD BLOCKS PER 6/5 DETAIL