Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
12/22/2015 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
10/19/2015 REINFORCED MASONRY PRE-GROUT Partial Approval AMPHITHEATER- PARTIAL- BASE WALLS TOPPED OUT
OK TO GROUT
09/30/2015 REINFORCED MASONRY PRE-GROUT Partial Approval EAST RETAINING WALL AT BRIDGE; TRASH ENCLOSURE OK TO GROUT PROGRESS
09/14/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/14/2015 REINFORCED MASONRY PRE-GROUT Partial Approval 1ST LIFT FOR HANDICAP RAMP-OK TO GROUT PROGRESS AREAS
07/27/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/27/2015 REINFORCED MASONRY PRE-GROUT Partial Approval SITE/SCREEN WALL SW CORNER AT 4'-8'
07/23/2015 REINFORCED MASONRY PRE-GROUT Partial Approval RETAINING WALL AT S.W. CORNER 48" AFFE
OK TO GROUT PROGRESS
07/13/2015 REINFORCED MASONRY PRE-GROUT Partial Approval NE CORNER TOP OUT OK TO GROUT PROGRESS AREAS GL: 1/C-C2; C/1-1.25
07/10/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 20'4"
GL: 1/C-C.2; C/1-1.25 OK TO GROUT PROGRESS AREAS
07/09/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 13'4-16'4" AT GL 1/C-C2; C/1-1.25 OK TO GROUT PROGRESS AREA
06/26/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 20'-22' GL:C/1.5-4 OK TO GROUT
06/24/2015 REINFORCED MASONRY PRE-GROUT Partial Approval NORTH WALL @20'-22'4" GL 1/C-D SOUTH WALL @ 20'-22'4" GL 4/C-D OK TO GROUT PROGRESS AREAS
06/19/2015 REINFORCED MASONRY PRE-GROUT Partial Approval WEST WALL AT 22' TOP OUT GL: D/1-4
OK TO GROUT PROGRESS AREA
06/15/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 16'-20' GL: 1/C.2-D; D/1-4; 4/C.2-D OK TO GROUT PROGRES AREAS
06/05/2015 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT TO 16' ON GL D: 1-4 AND GL 4: C-D
06/01/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/01/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 8'-12'; GL: D/1-4 - OK TO GROUT
05/29/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/29/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 8'-12' GL: 1/C.2-D; D/1-4; 4/C-D - OK TO GROUT PROGRESS AREAS
05/28/2015 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
05/21/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/21/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 4'-8' GL: D/1-3; 1/C-D; D/1-1.5; D/3-4; 4/C-D; C/2.8-4 - OK TO GROUT PROGRESS AREAS
05/19/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*