Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T14CM06962

Parcel: 115022610


Addresses:

221 E WAVERLY ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/09/2014 EXT METAL CLIPS/EXT SHEATHING Approved
12/04/2014 EXT METAL CLIPS/EXT SHEATHING Denied
12/04/2014 EXT METAL CLIPS/EXT SHEATHING Denied 1. ADD BLOCKING & NAIL OFF MOST PARAPETS
2. MISSING 1 ROOF ROW OF NAILS ON NEW BATH & 1 ON SOUTH PORCH
3. SW BED DOOR SHOULD NOT OPEN OVER STAIRS
4. MOVE PEX 12" FROM KIT CANS
5. INSTALL PROPER DRYER VENT DUCT
6. REPAIR OVER-NOTCHED KIT/BATH STUDS
7. NEED STUCCO MESH BEFORE FRAME PASSES