Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2015 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 11/04/2015 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* |
|
| 11/03/2015 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 10/10/2014 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 10/10/2014 | ELECTRIC - FINAL | Denied | 1. REPAIR WIRING S. SIDE OF STRUCTURE, LOOSE BOX, EXPOSED WIRING 2. INSTALL ADDRESS LABEL ON SERVICE EQUIP & PROPERTY TO BE VISIBLE FROM STREET 3. DOUBLE WIDE MH MOVED ON PROPERTY, PROVIDE PAST INSPECTIONS AND PERMITS FOR MH SET UP ON PROPERTY. FEEDER WIRE AND CONDUIT APPEAR TO BE NEW OR RECENTLY INSTALLED & NOT TO CODE |