Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/22/2014 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/19/2014 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/19/2014 EXT METAL CLIPS/EXT SHEATHING Denied 1. HOLD-DOWNS TO DOUBLE STUDS
2. NAIL OSB @ HOLD-DOWNS PER SHEER SCHEDULE
3. MISSING HARDWARE @ LEDGER CONNECTION REAR PORCH PER DETAIL 17/S6.1
4. MISSING CLIPS UPSTAIRS KING STUDS, HEADERS AND OVER SPANS
**STOPPED INSPECTION**