Permit: T14CM06539

Parcel: 108203080


Addresses:

4138 N FORTUNE LP

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
03/09/2015 MECHANICAL - INTERMEDIATE Approved
02/26/2015 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/24/2015 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/24/2015 MECHANICAL - INTERMEDIATE Denied B-VENT SHALL OFFSET NOT MORE THAN 60 DEGREES. SUPPORT PVC W/ APPROVED PIPE SUPPORTS NOT TO EXCEED 4'. INSTALL JOIST NAILS IN FHA STRAP AT TOP PLATE NOTCH AT DRYER VENT AND PROVIDE MIN NAIL PLATE