Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 05/20/2015 |
PLUMBING - INTERMEDIATE |
|
Approved |
|
| 05/12/2015 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 03/02/2015 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* |
| 03/02/2015 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
OK TO COVER. PROVIDE DOCUMENTATION FOR CHANGES FOR FINAL APPROVAL. GAS BOND REQUIRED #10. SEAL PIPE IN TUB BOX, TEST SHOWER. |
| 02/26/2015 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
DWV TEST OK. PROVIDE REVISION FOR CHANGE TO GAS PIPE SIZE. PROVIDE DOCUMENTATION FOR MATERIAL CHANGES; PIPE SLEEVE. CORRECT CONDENSATE SUPPORTS. SECURE CABLE AT DRYER BOX. TEST SHOWER. CAULK OR FOAM SHALL BE USED TO SEAL. |
| 02/24/2015 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 02/24/2015 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
GAS PIPING UNDER SIZED PER PLAN. SECURE CLOSET FLANGES. SEAL JOINTS OF PIPE INSULATE PEX MAX SUPPORTS 32". PLAN SPECS COPPER. REDLINE & PROVIDE DOCUMENTATION FOR CHANGES. PLAN SPECS METALLIC SLEEVE AT SOLAR |