Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T14CM06487
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/03/2014 | ELECTRIC - FINAL | Approved | ||
12/02/2014 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
10/06/2014 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
10/06/2014 | ELECTRIC - FINAL | Denied | 1. EXPOSE FOOTER PER WALL SECTION TO VERIFY 18' DEPTH 2. COMPLETE 3 WAY SWITCH CIRCUIT PER PLAN 3. SECURE ALL ROMEX 8" FROM BOXES THROUGHOUT 4. PANEL SCHEDULE CALLS FOR 2 NEW 20 AMP 12 GUAGE CRAIT 10& 11 IN GUAGE WE INSTALLED 5. PROVIDE CONNECTORS @ LIGHT CONNECTION BOXES 6. MISSING AFECT PER CODE @ CLOSET WALL WEST SIDE 7. INSTALL CAILING FAN BOXES 8. GROUND METER BOXES 9. DUCT WORK NOT INSTALLED 10 MISSING 4+4 WINDOW PER PLAN EAST WALL STOPPED INSPECTION |