Permit: T14CM06209

Parcel: 11106391A


Addresses:

2880 N EDITH BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/25/2014 PLUMBING - FINAL Approved IVRS - Inspection :*
09/24/2014 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
09/24/2014 PLUMBING - FINAL Partial Approval SECURE WATER HEATER VENT LOOSE JOINT BELOW ROOF FLAG POLOD VENT SHALL BE SECURED TO PREVENT DAMAGE
09/23/2014 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/23/2014 PLUMBING - FINAL Denied CORRECT WATER HEATER VENTING SECTION OF B VENT IS UPSIDE DOWN. SINGLE WALL MAY NOT ME USED IN BETTWEEN B VENT. PROVIDE AN OPERATINAL RELIEF VALVE. CARBON MONOXIDE DETECTOR GOES OUT SIDE OF BED ROOM, NOT PLUG ABANDON PIPING