Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/04/2014 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 12/01/2014 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 12/01/2014 |
PLUMBING - FINAL |
|
Not ready for Inspection |
HOSE THREAD & LAUNDRY TUB REQ VAC BREAKER TAP RELIEF VALVE MAY NOT TERMINATE AT LAUNDRY TUB BR SINK NOT SEALED CORRECT P TRAP NOT PROPERLY IN STALLED VACUUM RELIEF VALVE REQ ON COLD SUPPLY TO WH REQ PER CODE SEAL DF DISINFECTION |