Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T14CM06131
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/07/2015 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
05/07/2015 | REINFORCED MASONRY PRE-GROUT | Approved | INSPECTIONS COMPLETED BY J.M. AND B.B. | |
04/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
04/15/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
04/07/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
04/07/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT NEXT LIFT PENDING SPECIAL INSPECTION | |
04/06/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
04/06/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 3RD LIFT, NORTH WALL | |
03/31/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
03/31/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT NEXT LIFT AT WEST, SOUTH, & EAST WALLS | |
03/27/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
03/27/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT NEXT LIFT AT SOUTH & EAST WALLS | |
03/24/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
03/24/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO POUR TRASH COMPACTOR SLAB | |
03/23/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
03/23/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT 20' LIFT @ WEST WALL | |
03/20/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
03/20/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT 4TH LIFT AT EAST, SOUTH, & WEST WALLS PENDING SPECIAL INSPECTION | |
03/19/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
03/19/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO POUR LOADING DOCK SLAB | |
03/18/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 3RD COURSE. ALSO, COLS | |
03/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
03/16/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT 1ST LIFT SOUTH WALL GRID LINE B TO F, 1 TO 4 WEST WALL, F TO E ON NORTH WALL. OK TO GROUT STEM WALL AT ENTRY COLUMNS | |
03/06/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
03/06/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT FIRST LIFT AT LOADING DOCK |