Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T14CM06016

Parcel: 13014439B


Addresses:

4426 E 22ND ST


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T14CM06016

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
09/30/2015 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
06/22/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
06/22/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval PA WEST SIDE WALL FOOTINGS OK TO POUR
05/08/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
05/08/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval NEW CAR DISPLAY - WEST ENTRY TO RADIUS DISPLAY - OK TO POUR PROGRESS AREA
04/09/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
04/09/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval SITE WALL FOOTINGS; SOUTH & SE STEM WALL FOOTING APPROX 300' - OK TO POUR
04/07/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
04/07/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval PONY WALL FOOTING IN SERVICE AREA - OK TO POUR
03/06/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
03/06/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval CONTINUOUS FOOTINGS & 3 @ C7/F14 COLUMN FOOTINGS: GL: AA.0/15.0-16.0; 16.0/B.0-AA.0; Y.0/16.0-18.0; 18.0/U.0-Q.0; U.0/16.0-18.0; 19.0/B.0-F.0; B.0/16.0-18.0; B.6/16.0-18.0; F.0/ 16.0-18.0; C7/F14 GL: 16.0/Q.0; 16.0/N.0; 16/L.0
03/05/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
03/05/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval CONTINUOUS FOOTINGS & COLUMN FOOTINGS. GL: 1.0/B.0-V.0: 4 @ F6 COLUMN FOOTINGS @ GL: 1.0/P.5, N.0, K.7, E.0; B.0/1.0-3.5; 3.0/A.0-B.0; A.0/3.0-13.0; 13.0/A.0-B.0; B.0/13.0-16.0; ELEVATOR: E.0/4.0; STAIRWELL FOOTING @ R.0-5.0/8.0-8.5 - OK TO POUR PROGRESS AREAS
03/04/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
03/04/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval GL: B.1 @ 5 COLUMNS; D.0 @ 2; E.0 @ 1; J.0 @ 2 COLUMNS GL: 12.0 @ 3 COLUMNS
02/27/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
02/27/2015 EXCAVATION/LAYOUT REBAR & ZON Partial Approval CONTINUOUS FOOTINGS & COLUMN FOOTINGS; GL: 15/B.0-AA.0; 8/V.0-Z.0; 8.5/R.0-V.0; R.0/8.0-8.5; 8.0/R.0-V.0; V.0/8.0-8.5; X.0/4.0-8.0; 4.0/V.0-X.0; V.0/1.0-4.0 - OK TO POUR PROGRESS AREAS