Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 01/27/2015 |
MECHANICAL - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* |
| 01/23/2015 |
MECHANICAL - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* |
| 01/23/2015 |
MECHANICAL - INTERMEDIATE |
|
Partial Approval |
PROTECT CU FROM STUCCO (10 MIL PVC TAPE). TEMP HB REQ VAC BREAKER (ALL LIVE HB REQ VB). REQ 18 OF METALLIC TUBING FROM ANY FUTURE SWEAT CONN. SOFTENER DRAIN REQ AN AIR GAP (MAY NOT CONN TO TAIL). ISOLATE PEX FROM GANG NAILERS. |
| 01/22/2015 |
MECHANICAL - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |