| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/02/2015 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 01/22/2015 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/22/2015 | ELECTRIC - FINAL | Denied | 1. ACORN GROUND RODS 2. LABEL CIRCUITS 3. SMOKE ALARMS HALLWAYS 4. PROVIDE LETTERHEAD FROM LICENSED ELECTRICAL CONTRACTOR STATING ALL REPAIRS DUE TO VANDALISM ARE TO CODE FOR SAFETY 5. WHITE HOT LEADS TO BE BLACK OR RED (TAPE OK) |
|
| 01/16/2015 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/16/2015 | ELECTRIC - FINAL | Denied | SEE NOTES 3076 | |
| 01/16/2015 | ELECTRIC - FINAL | Denied | - EXPOSE ALL GROUND RODS FOR INSPECTION - 1 #4 PER ACORN CONNECTOR AT GROUND ROD - 2 GROUND RODS 6' MIN APART - EXPOSE #4 BARE - ADDRESS LABELS (PERMANENT) - NEW WIRING INSIDE UNITS REQUIRES APPROVED PLANS & PERMIT, APPROVED INSPECTIONS - PHONE # OF RECORD NOT CORRECT |